Validation of a force platform clinical for the assessment of vertical jump height
dc.career | Medicina | es |
dc.category.author | principal | es |
dc.contributor.author | Aladro Gonzalvo, Arián Ramón | |
dc.contributor.author | Esparza Yánez, Wilmer Danilo | |
dc.contributor.corresponding | Aladro Gonzalvo, Arián Ramón | es |
dc.country | Ecuador | es |
dc.date.accessioned | 2023-11-04T21:33:34Z | |
dc.date.available | 2023-11-04T21:33:34Z | |
dc.date.issued | 2017 | |
dc.dedication.author | TC | es |
dc.description.abstract | Objective: the purpose of the present study was to analyze the concurrent validity and reliability of a force platform clinical COBS Feedback for the estimation of the height of vertical jumps. Design: a cross-sectional correlational and comparative study. Setting: University Human Movement and Physiotherapy Laboratory. Participants: healthy university students (14 female and 13 male) aged between 18 and 25 years old (mean = 20.074 ±1.542). Main Outcome Measures: vertical jump heights, technical error and grade of agreement between methods of measurement. Results: after the 27 subjects performed a total of 135 vertical jumps on COBS Feedback platform while simultaneously being recorded with a high-speed camera-based method, the intraclass correlation coefficient showed an almost perfect concordance between the two methods (ICC = 0.916, CI95%= 0.882 to 0.940, p<0.001). The technical error of the COBS Feedback® against HSC-Kinovea video analysis was at 0.310±0.223m, being higher in males than in females (t= -2.822, CI95%: -0.376 to - 0.574, p=0.001). Conclusions: the COBS Feedback® method provided a valid measurement of the flight times for estimate the vertical jump height as a number of well-known tests and devices | es |
dc.faculty | Medicina | es |
dc.id.author | 1755823034 | es |
dc.id.author | 1711842128 | es |
dc.id.type | 1 | es |
dc.identifier.doi | https://doi.org/10.14198/jhse.2017.122.13 | es |
dc.identifier.issn | 19885202 | |
dc.identifier.uri | https://www.jhse.ua.es/article/view/2017-v12-n2-validation-force-platform-clinical-assessment-vertical-jump-height | es |
dc.identifier.uri | https://repositorio.puce.edu.ec/handle/123456789/5195 | |
dc.indexed.database | Scimago Journal Rank | es |
dc.list.authors | Aladro, A., Esparza, D., Tricas, J. y Lucha, M. | es |
dc.magazine.pageRange | 367-379 | es |
dc.magazine.title | Journal of Human Sport and Exercise. Universidad de Alicante | es |
dc.magazine.volumeChapter | 12(2) | es |
dc.rights | OpenAccess | es |
dc.state | published | es |
dc.subject | Biomecánica | es |
dc.subject | Terapia Física | es |
dc.subject | Rendimiento Atlético | es |
dc.title | Validation of a force platform clinical for the assessment of vertical jump height | es |